Model | LWSI-23-3.6KW | LWSI-23-5.6KW |
AC mode | ||
Rated Input Voltage | 220/230Vac | |
Input Voltage Range | (170Vac~280Vac) ±2%;(90Vac-280Vac)±2% | |
Frequency | 50Hz/ 60Hz (auto-detect) | |
Frequency range | 47±0.3Hz ~ 55±0.3Hz (50Hz) / 57±0.3Hz ~ 65±0.3Hz (60Hz); | |
Overload/short circuit protection | Circuit breaker | |
Efficiency | >95% | |
Conversion time (bypass and inverter) | 10ms (typical) | |
AC reverse protection | Available | |
Maximum bypass overload current | 30A | 40A |
Inverter mode | ||
Output voltage waveform | Pure Sine Wave | |
Rated output power (VA) | 3600 | 5600 |
Rated output power (W) | 3600 | 5600 |
Power Factor | 1 | 1 |
Rated output voltage (Vac) | 230Vac | 230Vac (200/208/220/240Vac can be set) |
Output voltage error | ±5% | |
Output frequency range (Hz) | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | 50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Efficiency | >92% | > 90% |
Peak Power | 6000VA | 10000VA |
Load Motor Capacity | 2HP | 4HP |
Output Short Circuit Protection | Circuit Breaker | Circuit breaker |
Bypass Breaker Specifications | 30A | 40A |
Rated Battery Input Voltage | 24V (minimum start-up voltage 22V) | 48V (minimum starting voltage 44V) |
20.0Vdc~33Vdc ± 0.6Vdc (under voltage alarm/off voltage over voltage alarm/over voltage recovery... (can be set on the LCD screen) | ||
Battery Voltage Range | ||
Power saving mode | Load ≤50W | |
AC Charging | ||
Battery Type | Lead acid or lithium battery | |
Maximum Charge Current | 80A | 60A |
Charging voltage range | 20.0Vdc~33Vdc | 40~60Vdc |
Short Circuit Protection | Circuit breaker and blown fuse | Circuit breakers and blown fuses |
Circuit breaker specification | 30A | 40A |
Overcharge Protection | Alarm and off charging after 1 minute | |
PV Charging | ||
Maximum PV open circuit voltage | 500Vdc | 500Vdc |
PV Operating Voltage Range | 120-500Vdc | 120-500Vdc |
MPPT Voltage Range | 120-450Vdc | 120-450Vdc |
Battery voltage range | 20-33Vdc | 40-60Vdc |
Max. input power | 4000W | 6000W |
PV charging current range (settable) | 0-80A | 0-80A |
Charging short circuit protection | Trip | Trip |
Wiring protection | Reverse wiring protection | Reverse wiring protection |
Certification specifications | ||
Certification | CE(IEC 62109-1) | |
EMC certification level | EN61000, C2 | |
Operating temperature range | -15°C to 55°C | |
Storage temperature range | -25°C ~ 60°C | |
Humidity Range | 5% to 95% (triple protection paint protection) | |
Noise | ≤60dB | |
Heat dissipation | Forced air cooling, fan variable speed | |
Communication Interface | USB/CAN/RS485(WiFi/GPRS)/Dry Node Control | |
Dimension (L*W*D) | 378mm*280mm*103mm | 426mm*322mm*126mm |
Weight (kg) | 6.9 | 10.9 |
In order to better serve customers, we now make the following disclaimer for the product information published on the website that contains text, pictures, and links:
1. The product picture may have a color difference with the actual product due to the different angle and light, as well as the display difference of the monitor. The picture is for reference only, the actual product shall prevail, please contact our staff for more details.
2. It is the customized product, not final retail product. Details, description, pictures, and specifications are subject to the final confirmed order.
3. The price is for reference only, the market price is fluctuating, and the price marked on this page is not the only basis for the final transaction. Please contact our sales staff to confirm the final price.